Bio-enhanced, superior performance PIR insulation suitable for Sarking Warm Roof construction. ECO360 MA, with a thermal conductivity as low as 0.020 W/mK, in a sarking warm roof application offers an environmentally conscious solution which provides improved detailing, speed of installation and a uniform plane to accommodate more efficient detailing.

This bio-enhanced insulation is lightweight, easy to install and combines high compressive strength with low thermal conductivity, providing a high performance solution for roof insulation

ECO360 MA is halogen free and the product packaging is bio-degradable while the overall packaging content has been reduced significantly.

  • Bio-enhanced PIR insulation

  • Enhanced performance as low as 0.020 W/mK

  • Halogen free

  • Bio-degradable packaging

  • Suitable for pitched roofs

ECO 360 MA Sarking Product Graphic

The pitched roof Sarking insulation shall be ECO360 ECO/MA Sarking manufactured to EN 13165 by Unilin Insulation, comprising of a rigid modified Polyisocyanurate (PIR) core with textured robust low emissivity foil facings. The ECO/MA _ _ mm with a declared Lambda value as low as 0.020 W/mK to achieve a U-Value of _ _ _W/m2 K for the roof element. To be installed in accordance with instructions issued by Unilin Insulation

Refer to NBS clause P10 140, K11 695, K11 55. Uniclass 25 71 63 66


The resistance value of any thickness of Unilin insulation can be ascertained by simply dividing the thickness of the material (in metres) by its Agrément declared Lambda value, for example: Lambda 0.020 W/mK and thickness 100mm -> 0.100/ 0.020 -> R-Value = 5.0. In accordance with EN 13165, R-Values should be rounded down to the nearest 0.05 (m2K/W).

1. ECO/MA offers a practical on-site solution that results in a more robust continuous layer of insulation, minimising the threat of Thermal Bridging and improving the overall U-Value of the roof.

2. Detailing with breather membranes and vapour control membranes can be more accurately achieved with insulation in a single plane. Adding an additional layer of Unilin ECO/MA between the counter battens minimises fixing length and improves the overall U-Value of the roof.